A compound microscope shows the letter e upside down because its lenses form an inverted image, and the eyepiece does not turn it back. The slide is a standard first-week lab exercise: it lets you check focusing, stage movement and magnification on a specimen whose real orientation you already know.
What you should see
Harrisburg Area Community College's general biology lab manual has students draw the letter e as it looks in their hand, then draw it again through the microscope. Its description of the result is that the letter appears upside down and facing left. In geometric terms that is a flip top to bottom plus a flip left to right, which together equal turning the page 180 degrees. A letter e is a good test subject because it has no mirror symmetry, so any flip is obvious.
Why the image is inverted
OpenStax College Physics breaks a compound microscope into two stages. The objective forms a first image that is larger than the object. That first image becomes the object for the eyepiece, which acts as a magnifying glass. The text says the final image is virtual and inverted, and that it stays inverted but sits farther from the observer, which makes it easy to view. In its worked example the objective has a magnification of -30.0 and the eyepiece 8.33, giving -250. The negative sign is how the book marks an inverted image.
The stage moves the "wrong" way
Because the picture is inverted, steering feels backwards at first. Monterey Peninsula College's lab guide says the inverted image always moves opposite to the direction you move the slide. The Harrisburg manual spells out the cases: slide moved to the left, the image appears to move right; slide moved down, the image seems to move up. Practise this with the e slide before you try to chase a moving organism.
Step by step with the e slide
- Draw the letter as it looks on the slide in your hand.
- Place the slide on the stage and secure it with the clips.
- Select the scanning (4x) objective, centre the letter in the field of view and focus with the coarse knob, then the fine knob.
- Draw what you see through the eyepiece.
- Rotate to the low-power (10x) objective and refocus using only the fine adjustment.
- Move the slide left, right, forward and back, noting the direction the image travels.
Harrisburg's manual also says decreasing the aperture of the iris diaphragm reduces the light on the specimen and increases contrast. Its quick-focus tip is to raise the stage fully and then lower it half a turn of the coarse knob before looking through the eyepiece.
Magnification you can work out yourself
Total magnification is the objective power multiplied by the eyepiece power. Monterey's guide gives the example of the eyepiece (ocular) fixed at 10x, so a 40x objective yields 400x. OpenStax says objective magnifications run from about 5x to 100x and that ordinary optical microscopes reach up to about 1500x with theoretical resolution around 0.2 micrometres.
| Objective | Eyepiece | Total magnification |
|---|---|---|
| 4x (scanning) | 10x | 40x |
| 10x (low power) | 10x | 100x |
| 40x (high power) | 10x | 400x |
Harrisburg's manual leaves the first two values for students to fill in; the table simply applies its formula, ocular power times objective power.
Parfocal lenses and safe focusing
Harrisburg explains that most microscopes are parfocal: once the specimen is in focus at the lowest power, it stays close to focus when you switch to a higher-power objective. Monterey's guide agrees that you will only have to adjust the fine focus slightly. Both guides set the same order of work. Start with the scanning objective, use the coarse knob only at low magnification, then move up in power using the fine knob. Harrisburg warns never to use the coarse adjustment at high magnification, and Monterey warns that doing so can easily break the lens and the slide.
Typical lab-report questions
- Is the image right side up or upside down? Upside down and reversed left to right.
- What happens when you move the slide toward you? The image moves away from you, opposite to the slide.
- Is the letter larger at 10x than at 4x? Yes, 100x against 40x with a 10x eyepiece.
- What is the total magnification at each setting? Multiply objective by eyepiece, as in the table.
If your own microscope differs from these guides, for example with a different eyepiece power, use the numbers printed on your lenses in the same formula.
Take this further with Oakgen Agent
Agent can write the lab guide and review questions, check magnification calculations in its sandbox and export the sheet as a docx or pdf.
Looking for a recap of one specific YouTube video? The YouTube Summarizer does that today.
Open this task in Oakgen Agent
The prompt is filled in for you. Nothing is sent until you press send.
Frequently asked questions
Why does the letter e look upside down through a microscope?
The lenses form an inverted image. OpenStax College Physics explains that the objective forms a first image larger than the object, the eyepiece then acts as a magnifying glass on that image, and the final image is virtual and still inverted. A Harrisburg Area Community College lab manual describes what students see with the e slide as upside down and facing left.
Which way does the image move when I move the slide?
The opposite way. A Monterey Peninsula College lab guide states that the inverted image always moves in the direction opposite to the direction in which the slide is moved. The Harrisburg manual gives the same result: move the slide to the left and the image appears to move right, move it down and the image seems to move up.
How do I calculate total magnification?
Multiply the objective's power by the eyepiece's power. OpenStax College Physics states that the overall magnification of a multi-element system is the product of the individual magnifications. In the lab guides, a 10x eyepiece with a 4x scanning objective gives 40x, with a 10x objective gives 100x, and with a 40x objective gives 400x.
Why should I only use the fine focus knob at high power?
The Monterey Peninsula College guide warns in capitals not to use the coarse focus knob under high power because it can easily break the lens and the slide. It also explains that the objective lenses are parfocal, so after focusing at low power you only have to adjust the fine focus slightly when you switch.
Sources
- Harrisburg Area Community College via Biology LibreTexts, BIOL 101 Lab Manual, 1.2 Microscopes, Exercise 2 (read 2026-11-19)
- Monterey Peninsula College via Biology LibreTexts, Marine Biology Laboratory, Plankton and Microscopes (read 2026-11-19)
- OpenStax, College Physics 2e, 26.4 Microscopes (read 2026-11-19)